Add user codes to the system. Soilwork discography rar. All modern alarm systems tell you what type of trouble conditions exist on the panel.

Sep 25, 2017 - NetworX. NX-148E-CF Commercial Fire. THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR. Care should be taken to plug in and restrain the A.C. Transformer after testing.

The panel notifies you with the yellow/orange triangle on the keypad that a trouble condition exist. On the Networx series (NX-4/NX-6/NX-8/NX-8E) you have a trouble condition command that normally helps installers to troubleshoot the alarm system. From the keypad type “*2”. If you have a LCD keypad on the system you can read of the display what type of error condition exist on the system, but if you have a LED keypad the error conditions is listed by a LED light on the keypad that burns according to a number. Each number represent a different error condition.

Caddx nx 8 programming manual

Below is a list of error conditions that the panel can show. LED 1 – “System Fault. Press 1 for more information. Below is a list of trouble conditions 1 – Overcurrent Fault 2 – Siren Trouble 3 – Box Tamper 4 – Expander Trouble 5 – Expander Low Battery 6 – Expander Box Tamper 7 – Expander Trouble 8 – Ground Fault LED 2 – Zone Tamper LED 3 – Zone Low Battery LED 4 – Zone Loss of supervision (Press the 4 key for more information) LED 5 – Zone Trouble (Press the 5 key for more information) LED 6 – Telephone Line Cut/Trouble LED 7 – Failure to communicate LED 8 – Loss of time and date. Hope the list helps you to identifying the trouble conditions on your panel.

Caddix Security Systems GE Interlogix (Caddx) Security Systems GE Interlogix manufacturers the security system (formerly known by the Caddx brand name). It interfaces to the Domain Controller via RS-232, as does the NX-8 with the NX-584 option. This feature is now supported on the Domain 3000 in the 3.0 release for an additional software charge. Please email to receive the key to turn on this layer. This system must be connected directly to a Domain 3000 serial port. It is not supported on the Lantronix, Global Cache GC-100, or on the Domain 2000 in the 3.2 release. Overview: • • • Installation • • • • • Ubiquity Software • • Security System Architecture GE Interlogix NX-8E OR NX-8 with the NX-584 In the picture at the right the security system is connected to the Domain Controller via RS-232 with a straight through cable.

How to program caddx nx 8 troubleshooting download

Wiring the Domain 3000 for the NX-8 with the NX-584 For the NX-8 with the NX-584 (but not the NX-8E - see below), the serial cable is a standard straight through RS-232 cable. Wiring the Domain 3000 for the NX-8E For the NX-8E (but not the NX-8 with the NX-584 - see above), the serial cable is a female-to-female crossover RS-232 cable. Program the Security System All programming is done from the LCD keypad of the security system. The factory default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. The factory default for the 'Go To Program' code is [9]-[7]-[1]-[3] for a 4-digit code or [9]-[7]-[1]-[3]-[0]-[0] for a 6-digit code.

To enter the Program Mode, press * 8. At this time, the five function LEDs (Stay, Chime, Exit, Bypass, & Cancel) will begin to flash. Next, enter the 'Go To Program Code' (FACTORY DEFAULT IS [9]-[7]-[1]-[3] for a 4-digit code or [9]-[7]-[1]-[3]-[0]-[0] for a 6-digit code. If the 'Go To Program Code' is valid, the 'Service' LED will flash and the five function LEDs will illuminate steady. You are now in the Program Mode and ready to select the module to program.

Segment 3 Data 1 disabled 2 disabled 3 disabled 4 disabled 5 disabled 6 disabled 7 disabled 8 disabled Segment 4 Data 1 disabled 2 disabled 3 disabled 4 disabled 5 Primary Keypad Function with PIN 6 Primary Keypad Function without PIN 7 Secondary Keypad Function 8 Zone Bypass Toggle Test the serial port of the Security System Connect the Security System to your PC with a commercially bought RS-232 cable. The full set up is: 9600 baud, 8, none, 1, none. Then, in the Hyper Terminal settings menu append line feeds both ways, and echo typed characters. Type 0128292A and enter. You should get the reply at the right or some other similar reply.

Note that changing the connector for the Domain Controller to your PC or power cycling the security system tends to get the security system 's serial connection in a funny state, so it is best to try typing the numbers a couple of times. Connect the cable If you have the NX-8 with the NX-584 board, connect a straight through RS-232 cable from the Domain Controller to the security system. If you have the NX-8E, connect a crossover cable from the cable adaptor of the NX-8E to the Domain Controller (you will often also need a gender changer). Note that the P-0003 cable should be connected to the serial header so that its connector is plugged into the NX8E board with the Red Edge of the ribbon cable closest to the bottom of the board. Software To add the NX-8E (or NX-8 with the NX-584) option, start by selecting the Security Systems layer of the Design Module.